The Dual Output DC Regulated Power Supply is designed for versatile applications requiring two separate voltage outputs. It combines precision and flexibility to meet various testing and power supply needs. Key features include:
“ CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode.
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 600 | 0 - ±32V | 0 - 10Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
“ CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode.
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 600-2 | 0 - ±32V | 0 - 20Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
“ CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode.
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 600-3 | 0 - ±32V | 0 - 30Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
“ CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode..
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 601 | 0 - ±32V | 0 - 5Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
“CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of 10% with ± full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode.
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 602 | 0 - ±32V | 0 - 2Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
“CROWN” made MULTI OUTPUT DC REGULATED POWER SUPPLY are constant Voltage & Constant Current type supplies , have high regulation for Load & Line Voltage variation . The supply can be use in independent & tracking mode . The supply are protected against short circuit & over load . The output current can be controlled to any value from 0 to maximum .
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
OUTPUT VOLTAGE | : | (A) 0 - 32V DC / 2 Amp (B &C) 0 - ± 15 V DC / 1 Amp (D) 0 - 5V DC / 5 Amp |
LOAD REGULATION CC | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CV | : | + 0.05% + 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for +10% variation input voltage |
RIPPLE | : | Less than 1 mV |
METER | : | (1) Two Digital meters to monitor the output voltage
& current of output A (2) One Digital meter to monitor the output voltage of output B&C, selectable by switch (3) One digital meter to monitor the voltage of output D |
PROTECTION | : | Against short circuit & over load |
“ CROWN “ offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode.
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 603 | 0 - ±32V | 0 - 1Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 604 | 0 - ±64V | 0 - 1Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 604 | 0 - ±64V | 0 - 2Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 606 | 0 - ±64V | 0 - 5Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 607 | 0 - ±64V | 0 - 10Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 1 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 608 | 0 - ±128V | 0 - 1Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | 2mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 609 | 0 - ±128V | 0 - 2Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | 2 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 610 | 0 - ±128V | 0 - 5Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | 2 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 611 | 0 - ±300V | 0 - 1Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 3 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |
CROWN offer best in class constant voltage current Dual Output DC Regulated Power Supply using linear technology offering all kind of protections with specification and features to meet customer requirements. Our power supply offer stabilized output voltage with low ripple in wide input variation of ±10% with full protection against Short Circuit & over load using fold back technology. The supply can be used in independent & tracking mode
CODE | OUTPUT VOLTAGE | OUTPUT CURRENT (MAX) |
---|---|---|
CES - 611 | 0 - ±300V | 0 - 2Amp |
INPUT VOLTAGE | : | 230V ± 10% AC 50 Hz |
LOAD REGULATION CV | : | ± 0.05 % ± 3mV From no load to full load |
LOAD REGULATION CC | : | ± 0.05% ± 1mA From no load to full load |
LINE REGULATION CV | : | ± 0.01 % ± 3mV for ±10% variation input voltage |
LINE REGULATIONCC | : | ± 0.01% ± 1mA for ±10% variation input voltage |
OPERATING MODE | : | Independent & Tracking mode |
RIPPLE | : | Less than 3 mV |
METER | : | Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply |
INDICATION | : | LED FOR CV & CC Operating Mode |
ACCURACY | : | ± 1% ± 1 Digit |
PROTECTION | : | Against short circuit & over load |