Crown Electronic Systems

High Voltage Breakdown Tester

High Voltage Breakdown Tester Manufacturers in Delhi

Crown Electronic Systems is a leading High Voltage Breakdown Tester manufacturer in Delhi, offering advanced testing solutions for insulation resistance and dielectric strength. Our High Voltage Breakdown Tester is designed to accurately measure the breakdown voltage of insulating materials, ensuring safety and quality compliance in industrial and laboratory applications. 📞 Looking for a High Voltage Breakdown Tester manufacturer in Delhi? Contact Crown Electronic Systems!! today!

    Our range of High Voltage Breakdown Testers in Delhi includes:
  • ✔ High-precision voltage measurement with digital display
  • ✔ Adjustable voltage levels for customized testing
  • ✔ Reliable and durable design for long-term use
As a trusted manufacturer of High Voltage Breakdown Tester in Delhi, we ensure superior performance, safety compliance, and precision engineering in every product.
📞 Looking for a High Voltage Breakdown Tester manufacturer in Delhi? Contact Crown Electronic Systems!! today!

High Voltage Breakdown Tester Suppliers in Delhi

Crown Electronic Systems is a reliable High Voltage Breakdown Tester supplier in Delhi, providing high-accuracy testing instruments for industrial, electrical, and research applications. Our High Voltage Breakdown Tester helps in determining the dielectric strength of insulating materials, ensuring safe and efficient electrical systems.

    As a leading supplier of High Voltage Breakdown Tester in Delhi, we offer:
  • ✔ Different models with various voltage ranges
  • ✔ User-friendly operation with digital control
  • ✔ Fast and secure delivery across Delhi and India
  • ✔ Competitive pricing with bulk supply options
With our expertise as a High Voltage Breakdown Tester suppliers, we deliver top-quality testing solutions for electrical manufacturers, laboratories, and R&D centers.
📞 Need a High Voltage Breakdown Tester supplier in Delhi? Get in touch with Crown Electronic Systems!! today!

High Voltage Breakdown Tester Exporters in Delhi

Crown Electronic Systems is a trusted High Voltage Breakdown Tester exporter in Delhi, supplying globally compliant and high-precision testing instruments to international markets. Our High Voltage Breakdown Tester ensures accurate and safe insulation testing, making it an essential tool for electrical safety and quality control worldwide.

    We export a wide range of High Voltage Breakdown Testers from Delhi, including:
  • ✔ Advanced testers with adjustable voltage levels
  • ✔ Highly accurate and efficient insulation breakdown analysis
  • ✔ Custom-engineered solutions for global industrial needs
    As a leading High Voltage Breakdown Tester exporter, we ensure:
  • ✔ Secure international shipping with premium packaging
  • ✔ Strict quality control for global compliance
  • ✔ Timely deliveries with cost-effective export solutions
If you are looking for a reliable exporter of High Voltage Breakdown Tester in Delhi, Crown Electronic Systems provides industry-leading testing solutions trusted worldwide.
📞 Searching for a High Voltage Breakdown Tester exporter in Delhi? Contact Us Today!!

High Voltage Breakdown Tester Manufacturer in Delhi

High Voltage Breakdown Tester

The High Voltage Breakdown Tester is used to assess the insulation strength of materials by applying high voltage and measuring breakdown points. It is crucial for testing the durability and safety of insulating materials.

Key Features:

  • Testing Voltage Range: Applies high voltage to test insulation.
  • Breakdown Detection: Measures the voltage at which breakdown occurs.
  • Digital Display: Provides clear readouts of testing results.
  • Safety Features: Includes safeguards to protect users and equipment.

**High Voltage Breakdown Tester Can Be Made As Per Customer Specification**
  
Mail us
HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/30mA AC Manufacturer in Delhi

CES 403

HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/30mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 3KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 3.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/30mA DC Manufacturer in Delhi

CES 404DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/30mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 3KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 3.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/30mA AC Manufacturer in Delhi

CES 405

HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/30mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 5KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 5.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/30mA DC Manufacturer in Delhi

CES 406DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/30mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 5KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 5.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V DC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/100mA DC Manufacturer in Delhi

CES 407

HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/100mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 5KV 100 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 5.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/100mA DC Manufacturer in Delhi

CES 408 DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 5KV/100mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 5KV 100 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 5.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V DC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA AC Manufacturer in Delhi

CES 409 AC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 10KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 10.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA DC Manufacturer in Delhi

CES 409DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 10KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 10.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V DC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 20KV/30mA AC Manufacturer in Delhi

CES 410

HIGH VOLTAGE BREAKDOWN TESTER 0 - 20KV/30mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 20KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 20.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
DIMENSIONS : L 40cm. W.35cm. H.20cm
HIGH VOLTAGE BREAKDOWN TESTER 0 - 15KV/30mA DC Manufacturer in Delhi

CES 411DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 15KV/30mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 15KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 15.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V DC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA DC Manufacturer in Delhi

CES 411

HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/30mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 15KV 30 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 10.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/100mA AC Manufacturer in Delhi

CES 413

HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/100mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 3KV 100 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 3.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/100mA DC Manufacturer in Delhi

CES 413DC

HIGH VOLTAGE BREAKDOWN TESTER 0 - 3KV/100mA DC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 3KV 100 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 3.00KV DC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/100mA AC Manufacturer in Delhi

CES 414

HIGH VOLTAGE BREAKDOWN TESTER 0 - 10KV/100mA AC


CROWN" High Voltage Breakdown Tester is useful for measurement of Breakdown Voltage of Electrical Transformer, Cables & Wires Insulation Material & Components Etc. The Output Voltage & Leakage Current Limit is Settable As Required & Can be Monitor on Digital Meters The Instrument is Also Available With 3 Digit Digital Timer Settable From 1-999 Sec.

SPECIFICATION
OUTPUT VOLTAGE TEST CURRENT
0 - 10KV 100 mA
CURRENT LIMIT : Settable from 10% to 100% through continuouly Variable control
METER : Two Digital meters to monitor output voltage & Leakage Current
i. Digital KV Meter 0 to 10.00KV AC
Least Count : 0.01KV
ii. Digital mA Meter 0 to 199.9mA
Least Count : 0.1mA
ACCURACY : ± 1% of Reading
INDICATIONS : Lamp Indication for 'HT ON' & OF'
OUTPUT CABLE : 1.25(approx) Meter Long HV Cable with HV Probe fitted with Push Button for HT ON
POWER REQUIREMENT : 230V AC
TIMER (OPTIONAL) : 3 Digit, setable from 0 - 999sec
×
Send Us a Message
×
Send Us a Message